Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
R-40

40 HP, 230V Phase-A-Matic™ Rotary Phase Converter, UL Certified

Baldor Electric/Phase-A-Matic™ Design

The rotary portion of our converter is proprietary, custom built to our specifications by Baldor Electric, one of the largest and most trusted motor manufacturers in the world, with warranty stations nation and worldwide. It is a true phase converter and not a modified electric motor as most of our competitors use. Many years of testing, changing, and developing the converter in conjunction with Baldor’s engineers has produced a very simple and trouble-free converter with extremely low idle current and relatively low noise level. Many of our customers confirm that our rotary converters are the quietest and most trouble-free available, compared to other converters on the market.

Simplicity of design

Keeping the design exceptionally simple reduces the risk of electrical connection failure to almost zero since these are some of the most common causes of failure. We use only soldered connections with no mechanical electrical connections like spade clips, terminals or screws which can vibrate loose or corrode over time. There are no start capacitors, relays or contactors with connections which can come loose or arc and weld the contacts causing failure of the contactor and the start capacitors, and perhaps even the rotary converter or your equipment. Because of this we do not have circuit board failures caused by spikes generated by the magnetic contactors as some of our competitors do.

The Rotor

The Phase-A-Matic™ failure rate is practically zero because the rotors are specifically designed and manufactured for rotary converter use. However, some of our competitors emphasize that rotors often fail. This is because they machine standard electric motors, modifying and thereby weakening standard electric motor rotors, which were not originally designed to be used as a phase converter.

Testing before shipment

Every converter is performance tested before shipment and assigned a serial number. These records are kept for review if any questions should ever arise about the performance specifications.

Warranty Repairs

The most likely warranty repair would be bearings or windings, which are very rare. This type of failure is much less than 1%, and if it is going to happen at all, most likely would occur within the first 12 months. Failures after that are extremely rare. See MTBF below.

MTBF (Mean Time Between Failure)

Failure rate (MTBF) is so low it’s almost impossible to determine. We find that within the first 12 months approximately 1 in 150 might have a problem, and usually within a few weeks or months. After the first 12 months, it might be one or less in 5,000 over a 30 year period. We continue to hear of our Rotary Converters that have been in service for 25 or 30 years, and which are still working flawlessly. It could go on to do another 25 or 30 years. There is very little to go wrong with the Rotary Converter.

Multiple Motor Applications

Due to the high in-rush current required to start a motor, which can be as much as 5 to 10 times the normal running current, most applications require sizing the horsepower (HP) of the Rotary Converter 50% larger, OR MORE than the HP of the largest motor, or any combination of motors started at exactly the same time. The first motor started, IF NOT RUNNING HEAVILY LOADED, generates additional 3-phase power back into the circuit. You can then run additional motors (not heavily loaded and not all started at the same time). A maximum of up to 3 times the HP rating of the Rotary Converter can run at the same time, if not heavily loaded, and not started simultaneously. For example, a 3 horsepower converter could run motors totaling up to 9 horsepower under the specific conditions described here. See Installation.

Sizing Helps

Refer to Application Notes – additionally available in PDF form as RTN.pdf. Help is also available through the Sizing Assistance page. Just fill out the appropriate form and submit it to us. A qualified technician from Phase-A-Matic™, Inc. will contact you.
Call Phase-A-Matic™, Inc. 1-800-962-6976 for warranty repair stations in your area.

Uses include: metalworking and woodworking equipment, farm/agricultural equipment, pumps, compressors, refrigeration, elevators, printing machines, rectifiers, lasers, radar, EDM machines, MRI, tanning booths, transmitters, welders, conveyors, hydraulic pumps, flywheels, ovens, dough mixers, laundry machines, and virtually every type of 3-phase machine, including CNC/PLC equipment, when used with the Phase-A-Matic™ Voltage Stabilizer.

$5,439.00

Technical Notes

Rotary Model
R-40
Voltage
230V
Approximate Idle Current
14 A
Disconnect Switch Time Delay Fuse Current
150 A
NEMA Starter Size
4
Magnetic Starter Thermals Overloads Current
117 A
Minimum Single-Phase Supply Breaker Current
250 A
Free On Board (F.O.B.)
Palmdale, California
Largest Motor HP
25 HP

Specifications

Brand
Phase-A-Matic™
Unit Weight
410 lbs
Converter Series
R
Shipping Weight
460 lbs
Shipping Dimensions
31 x 24 x 24 in